Polaris

Polaris uses Copernicus and Galileo to find where shelters and medical tents can still work. A drone checks each site and drops a sensor; people go in only after it reports.

  • 0 Raised
  • 38 Views
  • 0 Judges

Tags

  • Romania

Categories

  • Challenge #2: Space-enabled crisis response and civil resilience

Gallery

Description

The vision

No medical team should walk into a place nobody has checked. When drones and debris hit a city, civil protection has to open shelters, first-aid points and aid corridors within hours, and today it does that from phone calls and guesswork. Polaris uses European space data to find the places that can still work, sends a drone to check each one and drop a sensor, and lets people in only after that sensor reports. It never says "safe". It says how long a place stays usable, how sure we are, and how much room is left.

The problem

  • Drones and debris now reach Romanian towns on the Danube. In Galați, a drone hit a block of flats on 29 May 2026. In Tulcea, explosive-armed debris was found on 29 Jun 2026.
  • The shelters on paper don't match the shelters that work. Romania's Court of Accounts found about 50% of civil-protection shelters non-operational. Galați county has 7 functional out of 206 (Puterea, 21 Jan 2026).
  • A working shelter can still kill. Generator CO in a sealed basement, CO₂ from crowding, a locked door.
  • Medical teams are sent blind. WHO has verified 3,000+ attacks on health care in Ukraine since 2022, and about 1 in 5 hit ambulances and other health vehicles (WHO Europe, 8 May 2026). Emergency medical services were attacked at least 110 times in 2025, mostly during rescue work and double-tap strikes (SHCC / Insecurity Insight). That's why medical-point locations can't be published.
  • The officer is half blind. GNSS is often jammed, so positions can't be trusted blindly, and phone networks may be down.

Our solution: Polaris

  1. Screen from space: where can a shelter or medical tent go? Unsuitable sites are ruled out first, each with its reason:VIKOR ranks the rest, using walking time to the population (GHSL), terrain cover, sensor evidence and data freshness.
    • Copernicus EMS damage and flood maps
    • Sentinel-1 radar: a calibrated open-water score, AUC 0.69 against EMSR758
    • the Copernicus DEM for low and steep ground
    • the hazard cordon
  2. Drone recon and sensor drop, in one sortie. No person installs a sensor in a danger zone. A site is VERIFIED only when both hold:A dangerous reading rejects the site.
    • the drone frame is clear, with a Galileo OSNMA-authenticated position
    • the dropped sensor has reported no gas, CO, smoke or jamming for a settle window
  3. Monitor inside once people are in. Encrypted, replay-protected ESP32 nodes report CO, gas, smoke, air quality, occupancy, doors and power over a quiet mesh. A certified gas alarm makes a site unusable at once. A node that goes silent is evidence too.
  4. Route people within capacity. A capacity-limited assignment (min-cost flow, under 20 ms on our sample scenario) sends each block of people to a place with room left, on the least-exposed walking route. It re-plans on every event.
  5. Humanitarian corridors. Least-exposed routes connect each medical tent to the nearest hospital (OSM) and an aid depot. They re-plan when a road segment goes BLOCKED. Only couriers and officers see them.
  6. A human approves every evacuation and every new site. Polaris is civil only: no targeting, no counter-drone, no public map of medical points.

Polaris answers "where can civilians and medical teams go, and is it still usable?" Our drone checks sites and drops sensors, and never tracks attackers.

What runs today (demo city: Galați)

  • Built and merged:
    • the shelter node firmware and gateway (encrypted frames, replay guard, liveness, local assessment)
    • the engine (time margins, capacity routing, officer approval)
    • route verdicts from EMS, drone replay, Sentinel-1 and nodes
    • the officer console and the Galileo alert-ellipse audit
    • the mesh simulator
    • site screening with VIKOR, the drone recon and dropped-sensor gate, and humanitarian corridors
  • Labelled on screen:
    • REPLAY: drone flights, from recorded frames
    • SIMULATED: drone-dropped nodes and the multi-hop mesh
    • SCENARIO: candidate sites and capacities

Target: Challenge 2, Space-enabled crisis response and civil resilience

Polaris answers the questions civil protection faces after a strike: where people can go, whether that place is still livable, and how medical teams and aid get there. It uses Copernicus, Galileo and ground sensors, and it keeps working when GPS is jammed. Positions are authenticated with Galileo OSNMA, and GNSS interference lowers the trust in any evidence near it.

The team

  • Voicu Delia (financial sector, including automation): the Copernicus layer (Sentinel-1 calibrated with the official LUTs, the open-water score fitted against EMSR758, the EMS footprints, the DEM walk graph with Tobler speeds); route verdicts that combine EMS, drone, Sentinel-1 and node evidence; the engine's capacity routing; site screening; humanitarian corridors.
  • Georgescu Gabriel (embedded software engineer, experience in the AI industry): the shelter node (ESP32-S3 with electrochemical CO, mmWave presence, particulates and gas); encrypted, replay-protected frames sized for LoRa; the gateway with its liveness check and local event assessment; the EU868 mesh simulator; the drone-placed sensor flow; the market research; the Polaris brand.
  • Tomescu Vlad (Java backend and frontend developer, 5 years in software): the officer console and Galileo alert audit; sign-in with roles; the drone view with land assessment, the terrain layer and route conditions (steps, freezing, steep); integration and code review; the 60 s demo; research on drones, the rules and prior art.

Team awards: 2nd place in Romania at the 11th CASSINI Hackathon · Techallenge award for indoor-monitoring sensors · 1st place at EESTEC Olympics 14.

Roadmap

  1. Next 6–12 months:
    • a pilot with ISU Galați and Galați City Hall on the county's 206 shelters
    • a real drone sortie with a dropped node
    • the LoRa mesh tested outdoors
    • application for EU UCPM / rescEU prevention funding
  2. Next 1–2 years:
    • extend to other Danube and eastern counties (42 ISUs)
    • a Polish or Baltic municipality pilot, where shelter budgets are far larger
    • real shelter lists in place of scenario data
    • add heat stress for crowded sites (Copernicus ERA5-HEAT)

Target customers

We sell where shelter money is already being spent. The buyer is the public body that must show the shelters it pays for actually work.

  1. Phase 1: city halls and their ISU. A 2026 amendment to Law 481/2004 lets city halls fund shelter repairs, and city halls hold the keys. The first customer to pitch is Galați City Hall with ISU Galați.
  2. Phase 2: ISU / IGSU nationally (42 county inspectorates) and owners' associations. Romania has 5,072 shelters on the Court of Accounts' list, and the €16.6 bn SAFE loan includes a €2.8 bn interior / civil-protection slice. Software eligibility isn't confirmed.
  3. Phase 3: Poland, the Baltics and Finland. Poland's Security and Defence Fund has PLN 9.65 bn for shelters, Finland has 50,500 shelters and Lithuania has 6,513. EU UCPM is proposed at €10.7 bn for 2028–34.

The public is not a buyer. Civilians get only a shelter's location and a status band.

Cost (ESTIMATE)

  • Shelter node: about €250 installed. The parts are about €80–120: ZE03-CO, LD2410, PMS5003T, MQ-5 and ESP32-S3. A comparable indoor-air sensor costs £200 for the hardware alone.
  • Galați pilot: about €52k of hardware for 206 shelters.

Revenue (ESTIMATE; no buyer interviewed yet)

  • €120 per node per year for monitoring, capacity and routing. Airthings sells air monitoring alone at about $72 per device per year.
  • €20–40k per year for a county platform licence. Juvare WebEOC costs $11.7k–99k per year, depending on the number of users.
  • Galați pilot (SOM): about €50k per year.
  • Romania (SAM): about €1.4–2.3m per year.
  • Known eastern-flank and Nordic shelters: about €7.5m per year, before platforms.
  • The pitch: we are the proof that the billions being spent on shelters produced shelters that work, and keep working. That proof is checked by inspection visits today.

Links

Repo: https://github.com/Arlechino00/Polaris

Attachments